The Model AX2 / AX2DL is a two channel vehicle detector with one relay output per channel.
- Six external DIP switches per channel
- Directional Logic option
- Two detectors in a single box
|
- Single Relay output per channel:
- True Presence TM
- Pulse-on-Entry
- Four levels of sensitivity selectable from the front panel
- Sensitivity Boost for applications where high-bed vehicles might be encountered
- Power Down Memory: enables the detector to automatically track the status of the loop during power interruptions of any duration
- Fail LED indicates current loop failures or loop failures that have occurred
- Four loop frequencies selectable from the front panel
- Channel scanning
- Super bright LED indicators for power, detect/loop fail
- Single 11-pin connector or Dual 11-pin connector models available
- Fail-Safe or Fail-Secure versions available
- Directional Logic on AX2DL versions
- 3.00" High x 1.75" Wide x 4.30" Deep
|
|
Ordering information:
Model AX2-y-wC-z (xx) or AX2DL-y-wC-z- (xx)
|
|
| |
y = |
3: 120 VAC Input Power
4: 10-35 V AC/DC Input Power
8: 240 VAC Input Power
Intentionally Left Blank |
| |
w = |
1: Single Connector
2: Dual Connectors
Intentionally Left Blank |
| |
z = |
Blank: Fail-Safe |
| |
|
S: Fail-Secure
Intentionally Left Blank
|
| |
xx = |
NC: Normally Closed Relay Contacts*
NO: Normally Open Relay Contacts*
Intentionally Left Blank |
| |
* 2C (Dual Connector) models do not use the (NO) Normally Open or (NC) Normally Closed contact designation. Both contacts are accessible for each channel.
Intentionally Left Blank |
AX2 with 1 Connector (1C) requires 802-4-2TP or 802-4-2TP-S harness, or SKT-11 relay socket base.
AX2 with 2 Connectors (2C) requires two of 802-4-S or 802-4-2TP-S harnesses.
Intended to be left blank
|
| |
|