The Reno A&E Model 242 is optically isolated from the input using an Optoisolator. Each isolated channel is equipped with a test switch that allows for a simulation of a valid input signal. Each channel has two light-emitting diodes (LED): a red LED (OUT) that indicates a call and a red LED (FAULT) that indicates fault status.
- Exceeds CALTRAN TEES Standards
- AC line input voltage: 89 VAC to 135 VAC, 50/60Hz
- AC Input Power: ≤2.5W (max)
- AC input - fuse protected
- I/O Insulation: ≥1000 Megaohms
- I/O Isolation Voltage: ≥3000VAC RMS
- Channel Output to Controller: Open Collector
- Output Time: 100 msec minimum hang time for call
- Fault Detection and Indication for each channel
- Connector: 2 x 22 contact card edge connector with a 0.0156-inch contact center with keyed slots.
- Operating Temperature: –40ºC to +85ºC
- Dimensions: 1.12” W x 4.50” H x 6.875” D. Handle adds 1.00 inch to depth dimension
|
|
|