- 0.375" Nominal O.D. (for use in 1/8" or 1/4" saw slots)
- Installed prior to sealing saw slots
- Holds loop wires and lead-in wires securely in saw slots and keeps loop wires and lead-in wires from floating to the surface when sealant is applied
- Use 1” to 2” long pieces spaced approximately 2 feet apart
- Reno A&E p/n 390-0250-00
|
|
|
|
LW-120: Single Conductor Loop Wire |
 |
- 0.118” Nominal O.D. (for use in 1/8” saw slots)
- For light traffic applications with stable road surfaces such as residential gates or loops cut in concrete floors
- Available with Black, Red, or Blue insulation
- Reno A&E p/n 381-2000-00 (Black), 381-2020-00 (Red), or 381-2060-00 (Blue)
|
|
|
|
LW-116: Single Conductor Loop Wire |
 |
- 0.216” Nominal O.D. (for use in 1/4” saw slots)
- For heavy traffic applications and industrial / commercial installations
- Insulation color - Orange
- Reno A&E p/n 381-1600-01
|
|
|
|
LW-116-P: Single Conductor, Single Jacketed Loop Wire |
 |
- 0.156” Nominal O.D. (for use in 1/4” saw slots)
- For heavy traffic applications and industrial / commercial installations
- Insulation color - Orange
- Reno A&E p/n 381-1603-00
|
|
|
|
LW-116-S: Single Conductor, Double Jacketed Loop Wire |
 |
- 0.240” Nominal O.D. (for use in 1/4” saw slots)
- For heavy traffic applications and industrial / commercial installations where additional insulation protection is needed
- Insulation and outer jacket color - Orange
- Reno A&E p/n 381-1601-01
|
|
|
|
HR-216: Two Conductor Lead-in Cable |
 |
- 0.275” +\- 0.020” Nominal O.D. (for use in 3/8” saw slots)
- Twisted pair lead-in cable for long lead-in runs
- Outer jacket color - Orange
- Conductor insulation colors - Black and White, twisted eight (8) times per foot
- Reno A&E p/n 380-0002-01
|
|
|
|
LW-216-HD: Two Conductor, Double Jacketed Lead-in Cable |
 |
- 0.360” +\- 0.020” Nominal O.D. (for use in 3/8” saw slots)
- Twisted pair lead-in cable for long lead-in runs where additional insulation protection is needed. Used in Reno A&E’s Model PLH preformed loops
- Inner and outer jacket color - Orange
- Conductor insulation colors - Black and White, twisted eight (8) times per foot
- Reno A&E p/n 380-0202-03
|
|
|
|
RR-216: Two Conductor, Triple Jacketed Lead-in Cable |
 |
- 0.750” Nominal O.D. (suitable for direct burial)
- Twisted pair lead-in cable for direct burial in gravel or other abrasive roadway bases. Used in Reno A&E’s Model PLH-R preformed loops
- Outer jacket color - Red
- Inner and middle jacket color - Orange
- Conductor insulation colors - Black and White, twisted eight (8) times per foot
- Reno A&E p/n 380-0402-00
|
|
|
|
HR-418: Four Conductor Cable |
 |
- 0.290” +/- 0.010” Nominal O.D. (for use in 3/8” saw slots)
- Four conductor home run cable (also refered to as magnetometer wire or 138 cable)
- Outer jacket color - Orange or black
- Conductor insulation colors - Black, Red, White, and Green
- Conductors are laid in a left hand direction, in the order listed above. Length of lay is 3” maximum
- Reno A&E p/n 380-0504-00 (Orange) or 380-0504-01 (Black)
|
|
|
|
LW-418: Four Conductor, Double Jacketed Cable |
 |
- 0.360” Nominal O.D. (for use in 3/8” saw slots)
- Four conductor cable used in Reno A&E’s Model PLH and Model PLC preformed loops
- Inner and outer jacket color - Orange
- Conductor insulation colors - Black, Red, White, and Green
- Conductors are laid in a left hand direction, in the order listed above. Length of lay is 3” maximum
- Reno A&E p/n 380-0004-01
|
|
|
|
RR-418: Four Conductor, Triple Jacketed Cable |
 |
- 0.750” Nominal O.D. (suitable for direct burial)
- Four conductor lead-in cable used in Reno A&E’s Model PLH-R direct burial preformed loops
- Outer jacket color - Red
- Inner and middle jacket color - Orange
- Conductor insulation colors - Black, Red, White, and Green
- Conductors are laid in a left hand direction, in the order listed above. Length of lay is 3” maximum
- Reno A&E p/n 380-0404-00
|
|
|
|